How we evaluate
An evaluation takes one version of your tool, the use you say it is for, and a set of test cases. We run the cases, read what the tool wrote, and check it against the source it was given.
What we evaluate
Clinical AI that takes text in and gives text out: scribes and note generators, summarizers, and chat assistants. We do not evaluate imaging, signal analysis or anything that reads a device output.
What we measure
- Faithfulness to the source. We count hallucinations, meaning content the source does not support, and omissions, meaning relevant source detail the output leaves out. Each hallucination is typed: fabrication, negation, causality or contextual.
- Consistency. We run each case more than once and compare the outputs for differences that matter.
- Bias. We probe for race-based medical claims that have been discredited, and we compare error rates across the patient groups in the test set.
- Transparency. We check whether your own documentation states the tool's intended use, its limits and its known risks.
How an evaluation runs
- You tell us what the tool is for, who uses it, and what it must not do.
- We build a test set of at least 25 cases from public and synthetic material, and we record where each case came from.
- We freeze the tool's version and settings and run every case three times. One run is scored in full. The other two are compared against it.
- One reviewer scores each output against its source, sentence by sentence. The reviewer is T&E's cofounder and is not a clinician.
- A panel of language models scores the same outputs as a second pass. Where the panel and the reviewer disagree, the reviewer looks again and makes the final call. The report names the models.
- We write the report. You may correct facts about your product. You may not change findings.
What the report contains
- The tool, its version and the test dates
- The intended use, in your words
- The test set: sources, size and kinds of cases
- Hallucination and omission rates with raw counts, by type
- The errors themselves, quoted beside their source passages. A sample if there are many
- Consistency and bias results
- Who scored the outputs and how
- What the test could not show
- Who paid for the evaluation
What an evaluation does not tell you
- How serious any error is for a patient. No clinician reviews the outputs.
- Whether your tool is a medical device, or anything else the FDA decides.
- Whether the tool is safe in live care. Results cover one version and one test set.
- How the tool compares to a clinician.
T&E holds no outside accreditation as a testing lab.
Independence
The fee is fixed before testing starts and does not depend on the results. Every report says who paid. We take no equity, commission or referral fee from a company whose tool we test, and we never evaluate a tool we helped build.